Therapeutic multilaser medical complex – HELIOS-711D

Objective

Implementation of various types of procedures simultaneously from 1 to 14 patients with various pathologies

HELIOS-711D/

Stage:/

Industrial production/

Therapeutic complex HELIOS-711D – integrated laser center, which includes 7 function-independent therapeutic laser systems for outside, internal, contact and non-contact influence by Red, IR junction lasers, including combined action with permanent magnetic field and laser-activated water. All systems operate independently and separately according to the selected mode.

Complete the form below to get more information: /


HELIOS-711D/

Stage:/

Industrial production/

Laser therapy is a comprehensive and coordinated action at the level of cells, tissues and organs, control, and working systems of an organism.

At the level of the whole organism, laser therapy provides a multifaceted action: regenerative, immunostimulant, anti-inflammatory, anti-edemic, desensitizing, normalizing metabolism and gas exchange, improving microcirculation.

Through influence on organs, projections of organs, receptive fields, reflexogenic zones and corporal acupuncture points by constant, modulated and pulsed red and infrared laser irradiation occurs high clinical efficiency in the treatment of a wide range of diseases.

Laser therapy complements and goes well with medicamental methods, surgery, physiotherapy, chemotherapy, homeopathy, aromatherapy, balneology and other therapies and prevention treatments. Therapeutic complex HELIOS-711D can function as a treatment for a narrow range of diseases (e.g., urology and cosmetology) and for general use in all areas, implementing procedures simultaneously to 14 patients with various pathologies.

Complete the form below to get more information: /


HELIOS-711D/

Stage:/

Industrial production/

  • Management of the database of the patients
  • Compiling a personal course of treatment with a selection of optimum techniques
  • Management of the database known and again of designed techniques of treatment
  • Convenient and fast access to all resources of center for selection of different operational modes
  • Automatic calculation and control of the main specifications of a procedure for each laser system separately and totally
  • A Large band of a power control and modulating frequency of laser generators

Complete the form below to get more information: /


HELIOS-711D/

Stage:/

Industrial production/

  • Multifunctionality
  • 7 function-independent therapeutic laser systems for outside, internal, contact and non-contact influence
  • All systems operate independently and separately
  • From 1 to 14 patients simultaneously
  • Treatment of a wide range of diseases (up to 100 diseases) and syndromes of a various body systems
  • Management of the database of the patients
  • Compiling a personal course of treatment with selection of optimum techniques
  • Management of the database known and again of designed techniques of treatment
  • Convenient and fast access to all resources of center for selection of different operational modes
  • Automatic calculation and control of the main specifications of a procedure for each laser system separately and totally
  • Large band of a power control and modulating frequency of laser generators

Complete the form below to get more information: /


HELIOS-711D/

Stage:/

Industrial production/

  • Central and peripheric nervous systems
  • System of a blood circulation
  • Systems of respiration
  • Organs of digestion
  • Genitourinary system
  • Locomotorium
  • Surgical pathology
  • Otorhinolaryngological diseases
  • Dentistry
  • Dependence
  • Dermatology
  • Cosmetology

Complete the form below to get more information: /


HELIOS-711D/

Stage:/

Industrial production/

Parameters of radiation Red laser Infrared modulated Infrared impulsive
Wavelength (Microns) 0.63 – 0.65 0.81 – 0.89 0.80 – 0.95
Modulating frequency (Hz) continuous 0 – 10000 1 – 500
Discretization of frequency setting (Hz) 0.01 in range of 0 – 100 Hz, 1.0 above 100 Hz 0.01 in range of 1 – 100 Hz, 1.0 above 100 Hz
System’s mean output power (MHW) scanner 35 – 40 80
IR – modulated 100
IR – impulsive 5 – 8 W (impulsive)
ICI 15
LBI, ILBI 5 -10
hydrolaser 15 – 20 100